Home / Reference Designs / TIDM-02013

Magnetics for the TIDM-02013 7.4 kW bidirectional onboard charger

TIDM-02013 is a Texas Instruments reference design for a 7.4 kW bidirectional onboard charger on GaN: a two-phase totem pole PFC followed by a full-bridge CLLLC that runs at 500 kHz nominal. The design guide publishes the magnetising inductance, the inductance ratio and the turns ratio of the CLLLC transformer, and the PFC inductance it calculates. The bill of materials shows that the transformer and the coupled PFC inductor are board-specific parts with no public datasheet, and that there is no separate resonant inductor: the tank inductance has to come from the transformer itself. We build these parts from the published values or from your modified ones.

Send your specs

What the board is

  • 90 to 264 V AC input, 240 V AC typical, up to 32 A RMS, power factor of 0.99 or better.
  • Two-phase totem pole PFC with LMG3522R030-Q1 GaN switches at 120 kHz, 400 V DC link (400 to 450 V).
  • Full-bridge CLLLC with active synchronous rectification, 500 kHz nominal and a 200 to 800 kHz control range, 250 to 450 V on the battery side, 20 A maximum, 7.4 kW.
  • One C2000 microcontroller (TMS320F280039C, or TMS320F28P65x) controls both stages.
  • 96.5 % peak system efficiency (98.5 % PFC, 98 % CLLLC) at 3.8 kW/L open frame.

Texas Instruments TIDM-02013 product page (`rel="noopener nofollow"`)

Source: Texas Instruments TIDM-02013 product page, design guide TIDUF18A (October 2022, revised February 2024), schematic TIDMAX0 and bill of materials TIDMAX1 for the PMP22650 E2 base board and the PMP22712 and PMP22773 cards, checked November 2026. See TIDM-02013 in our reference design table.

The magnetics on the board

Magnetics on TIDM-02013
PartWhat the design files publishWhat decides the design
CLLLC transformer, T1Design guide: Lm = 14 µH, picked by simulation below a 20 µH ZVS limit; Ln = Lm / Lrp = 14; turns ratio 1.1:1 in the tank design section and 1.33 in the test procedure; 500 kHz nominal, 200 to 800 kHz. BOM: Cyntec VT-20163, through hole, 73 × 51 mm footprint. The schematic has no separate resonant inductor on either side.Leakage on both sides, because it is the resonant inductance; Lm tolerance for ZVS; AC resistance at 500 kHz with a large magnetising current; insulation between the 400 V bus and the battery
Resonant capacitors, C2 to C17Four 33 nF, 630 V C0G capacitors in parallel on each of the four bridge legs, 132 nF per legNot a magnetic, but they fix the tank together with the transformer leakage
Coupled PFC inductor, L18Design guide: 126 µH from its ripple equations. BOM: Cyntec VI-20174A, described as "Coupled PFC", radialSelf and mutual inductance of the two coupled phases, core loss at 120 kHz on a 50 or 60 Hz current, inductance held at peak current
EMI common mode chokes, L16 and L17BOM: Renco FRM-DOC-15. The thermal section names the EMI common mode inductors as the hottest parts seen from the top, because they have no access to the cold plateCommon mode inductance at the conducted EMI band, and copper loss at 32 A RMS cooled by air only
Rogowski coils, T2 and T3BOM: Renco RLTI-1371 (primary) and RLTI-1379 (secondary). The schematic threads a 12 AWG wire or the transformer lead through each coil to sense tank current for synchronous rectificationMutual inductance and bandwidth at 500 kHz, position next to the transformer
Optional inductor, L19BOM: Cyntec VI-20173B, "OBC Resonant Inductor", 50 µH, not fitted. The schematic places it with two switches, also not fitted, between the primary transformer node and the other leg, under the net name CLLLC_LC_CHANGENot used on the published build
Bias transformers, PMP22712 cardWürth 901-20113-V1-01, 1:1, 80 µH, 3500 V AC, driven by the SN6501-Q1Isolation and interwinding capacitance for the gate drive supplies

Checks we ran on the published values

  • With Lm = 14 µH and Ln = 14, the design guide's resonant inductance would be Lrp = 1.0 µH, which resonates at 500 kHz with about 101 nF.
  • The board has 132 nF on each primary leg. The two legs are in series in the tank loop, so the effective Crp is 66 nF. With 1.0 µH that would resonate at 620 kHz, not at the 500 kHz nominal. To resonate at 500 kHz, 66 nF needs about 1.54 µH. So the leakage of the built transformer is about 1.5 µH per side, and with it Ln is about 9.1, not 14.
  • The turns ratio is given as 1.1:1 in the tank design and as 1.33 in the test procedure, where 400 V on the primary gives about 300 V on the battery side. At unity gain, 1.1:1 would put the battery at about 364 V and 1.33 at about 301 V.
  • At 500 kHz and 400 V, Lm = 14 µH gives a magnetising current of 14.3 A peak, 8.3 A RMS. At 300 V and 19 A on the battery side, one of the test points in the guide, the load current seen on the primary is about 15.9 A RMS (first harmonic approximation, n = 1.33). The magnetising current raises the primary RMS current to about 17.9 A: 13 % more current and 27 % more I²R loss in the primary winding. That is the price of ZVS on GaN at 500 kHz, and it is why the transformer winding cannot be sized from the load current alone.
  • For the same reflected voltage, the volt-seconds per half period at 200 kHz are 2.5 times those at 500 kHz. The core has to be checked at the low-frequency corner of the control range, not at the nominal point.
  • The 126 µH PFC inductance can be reproduced from the guide's equation 17 with 400 V, 120 kHz and a ripple of 10 % of the peak current per phase at 7.4 kW, 240 V and 98.6 % efficiency, split over two phases: 125.6 µH.
  • With 33 °C coolant, the guide's transformer temperature plot shows the inside surface of the secondary winding as the hottest point, near 92 °C, the outside surfaces of the windings near 60 °C and the side of the core near 50 °C. The heat has to cross the winding to reach the core and the cold plate, so the inner layers set the limit.

What the public documents do not say

  • No datasheet for the Cyntec VT-20163: core shape and material, turns, wire, how the leakage is split between primary and secondary, Lm tolerance, insulation class and creepage.
  • No coupling coefficient, self inductance or saturation current for the coupled PFC inductor VI-20174A.
  • No inductance or current rating for the FRM-DOC-15 common mode chokes.
  • No loss breakdown for the magnetics.
  • Why the optional L19 is 50 µH and when it would be fitted.

If you change the design

  • An 800 V battery doubles the secondary voltage. The turns ratio, the secondary insulation and the leakage split all change, and the 630 V resonant capacitors on the secondary legs no longer fit.
  • More power at the same frequency increases the load current but not the magnetising current, which Lm fixes for ZVS. Its share of the primary RMS current falls, but the core and the winding of the CLLLC transformer have to grow, or move to a planar build.
  • A SiC version at a lower frequency allows a larger Lm, because equation 3 of the guide scales with the switching period. It also raises the volt-seconds in proportion, so the transformer gets bigger.
  • A 230 V or 120 V only input changes the PFC inductor current and ripple, and with the coupled inductor both the self and the mutual inductance have to be recalculated.

What to send us

The reference number, your Lm, leakage target, turns ratio and frequency range if you changed them, battery voltage range and power, the insulation standard, the case dimensions, the cooling method and the quantities you expect.

We aim to send an engineering answer with a first design proposal inside 24 hours, then 4 to 8 weeks from an agreed design to a prototype, subject to raw material stock. No minimum order quantity.

Straight answers

TIDM-02013, the usual questions.

Is ConverNova a partner of Texas Instruments?
No. We are an independent designer and manufacturer of custom magnetics. We work from the public reference design and from what you tell us about your version of it.
Can you build the TIDM-02013 transformer without the Cyntec datasheet?
Yes. The guide gives Lm, the inductance ratio, the turns ratio and the frequency range, and the board gives the resonant capacitance. The value to agree first is the leakage per side. The ratio in the guide points to 1.0 µH, but the fitted capacitors only resonate at 500 kHz with about 1.5 µH, so that is the value we design to unless your build differs.
Why is there no separate resonant inductor on the board?
At 500 kHz the tank needs only about 1.5 µH per side, which a transformer can provide as leakage. Integrating it removes two parts and their losses. The price is that the leakage has to be held to a tight tolerance and split evenly between primary and secondary, so that the tank behaves the same in both power directions.
What does the coupled PFC inductor change compared with two separate inductors?
With two coupled phases the ripple each phase sees depends on the self inductance and on the mutual inductance, not on one value. The guide gives 126 µH for the ripple target but not the coupling, so we design the coupled part from your ripple and current targets per phase and in total.