Off-the-shelf inductor, transformer and choke finder
Find the standard part first
Enter what the component has to meet. If a standard inductor, transformer or common mode choke already does, you get the part and where to buy it. If the nearest ones only come close, the value that is off is marked. Everything comes back in one table you can sort and trim, so you can decide whether close is close enough or whether the part should be designed.
Before you buy
A match on the datasheet is not a match in the converter.
The finder compares catalogue values. Most of those are quoted at zero DC bias, 25 degrees C and a small signal, and your converter runs at none of those. Read the conditions, not the number, and if you would like a second pair of eyes on a part before you commit to it, send us the part number and your operating point.
The method
How the finder works
You enter only the values that define the part. The finder searches the DigiKey catalogue for power inductors, transformers and common mode chokes, and returns every part that meets them, and the ones that come close, in a single table with price and stock at each distributor. No account, and no email unless you ask for the table by email.
The values for each component
- Power inductor: inductance, saturation current, RMS current and, if it matters, the switching frequency. The finder checks that against the self-resonant frequency of each part.
- Transformer: the topology (flyback, forward, push-pull, isolated buck, resonant, LED driver, PoE, gate drive or current sense), primary inductance, turns ratio, power and switching frequency.
- Common mode choke: the number of lines, rated current, and the common mode inductance or the impedance at 100 MHz.
Strict or flexible
Each value can be strict or flexible. A strict value also lists parts that miss it by up to 5 %, and a flexible one widens that to 30 %. A part that misses a value is never shown as a match, only as close, with the value that misses marked. DC resistance, size, maximum temperature and mounting come back as columns you can sort and trim.
Read the conditions, not the number
Catalogue values are measured under conditions that are rarely the ones in your converter, and they are not measured the same way by every manufacturer. Before you compare two parts, check:
- Saturation current. Manufacturers define it at different inductance drops, commonly 10 %, 20 % or 30 % below the zero-current value. Two parts with the same Isat on the datasheet can behave very differently at your peak current.
- RMS current. It is usually the current that raises the temperature by 20 K or 40 K in still air, depending on the manufacturer, and it does not include the core loss caused by your ripple.
- Inductance. It is measured at a small signal, at a test frequency such as 100 kHz, and at about 25 °C. Your operating point has DC bias, a large AC flux swing and a higher temperature.
- Transformer isolation. A test voltage is not an insulation class. Check whether the part is rated for functional, basic or reinforced insulation, and at which working voltage.
- Common mode chokes. The impedance at 100 MHz says little about the band where your conducted emissions fail. Look at the full impedance curve.
When a standard part is not enough
In the first iterations of a project, a catalogue part is often the fastest way to test the converter. When nothing in the table holds at your real operating point, or the closest part is too large, too hot or close to end of life, send the same values to us as a custom specification from this page. We aim to answer within 24 hours.